Tutorials
CATEGORY DESCRIPTION
Lorem ipsum dolor sit amet consectetur. Rhoncus integer
Lorem ipsum dolor sit amet consectetur. Rhoncus integer
Home » Tutorials
Filter
Filter by Topic
Published: 22/03/2026 14:07:37
Intercom
Important Before Upgrading
Sunday, 22 March, 2026
1) NEW: DOOR BREACH DETECTION
The intercom now supports Door Breach Detection when connected to a door contact sensor.
If the door opens following an authorized action (such as unlocking from the intercom, mobile app, VMS, indoor monitor, or exit button), the event is treated as normal.
If the door opens without a valid access event, the system identifies it as a breach and can trigger configured responses such as alarms, audio alerts, snapshots, recordings, or output activation.
This allows the system to detect unauthorized door openings even when the main alarm system is disarmed.
If the door opens following an authorized action (such as unlocking from the intercom, mobile app, VMS, indoor monitor, or exit button), the event is treated as normal.
If the door opens without a valid access event, the system identifies it as a breach and can trigger configured responses such as alarms, audio alerts, snapshots, recordings, or output activation.
This allows the system to detect unauthorized door openings even when the main alarm system is disarmed.
Published: 22/03/2026 14:06:35
Intercom
1) NEW: DOOR BREACH DETECTION
Sunday, 22 March, 2026
2) NEW: FAIL-SAFE / FAIL-SECURE LOCK BEHAVIOR
A new configuration option allows defining how the door lock behaves if the intercom loses power (12V or PoE).
Two modes are supported:
Fail Safe – In the event of power loss, connected locks automatically unlock, allowing occupants to exit the building freely and prioritizing life safety.
Fail Secure – In the event of power loss, locks remain locked, maintaining security and preventing unauthorized access from the outside.
This configuration allows installers to choose the most appropriate behavior based on the building’s safety and security requirements.
Two modes are supported:
Fail Safe – In the event of power loss, connected locks automatically unlock, allowing occupants to exit the building freely and prioritizing life safety.
Fail Secure – In the event of power loss, locks remain locked, maintaining security and preventing unauthorized access from the outside.
This configuration allows installers to choose the most appropriate behavior based on the building’s safety and security requirements.
Published: 22/03/2026 14:04:33
Intercom
2) NEW: FAIL-SAFE / FAIL-SECURE LOCK BEHAVIOR
Sunday, 22 March, 2026
3) NEW: MULTIPLE AUTHENTICATION
This feature allows configuring group-based access authentication for high-security areas, adding an additional layer of security for sensitive areas where access should be granted only when multiple authorized users are present.
Instead of a single user unlocking the door, a predefined group of 2 to 5 authorized users must authenticate successfully within 60 seconds for the door to unlock.
If not all required users are authenticated within 60 seconds, the door remains locked.
Instead of a single user unlocking the door, a predefined group of 2 to 5 authorized users must authenticate successfully within 60 seconds for the door to unlock.
If not all required users are authenticated within 60 seconds, the door remains locked.
Published: 22/03/2026 13:26:35
Intercom
3) NEW: MULTIPLE AUTHENTICATION
Sunday, 22 March, 2026
4) NEW: FACE RECOGNITION SCHEDULE
Face recognition can now be limited to a defined schedule.
During the configured schedule, recognized faces trigger the normal unlock action. Outside the schedule, face recognition is ignored, and no unlock action is performed.
This allows installers to restrict face-based access to specific hours, such as staffed office or reception periods.
During the configured schedule, recognized faces trigger the normal unlock action. Outside the schedule, face recognition is ignored, and no unlock action is performed.
This allows installers to restrict face-based access to specific hours, such as staffed office or reception periods.
Published: 22/03/2026 13:19:35
Intercom
4) NEW: FACE RECOGNITION SCHEDULE
Sunday, 22 March, 2026
5) IMPROVED: TRANSPARENT WIEGAND TRANSMISSION
Improves integration with third-party access control systems using the Wiegand protocol.
When enabled, the RFID card number is transmitted via Wiegand regardlessof the authentication result.
When disabled, the card number is sent to the external controller only after successful authentication.
This ensures more accurate event logging and smoother coordination between the intercom and external access control systems.
Published: 22/03/2026 13:10:41
Intercom
5) IMPROVED: TRANSPARENT WIEGAND TRANSMISSION
Sunday, 22 March, 2026
6) IMPROVED: SIMPLIFIED BATCH IMPORT
The batch import process has been simplified.
Instead of selecting the CSV file and the face image folder separately, you can now select a single folder containing both files.
The system automatically detects the CSV file, matches each record to its corresponding face image, and imports all entries
in a single step.
Published: 22/03/2026 13:07:52
Intercom
6) IMPROVED: SIMPLIFIED BATCH IMPORT
Published: 22/03/2026 13:04:13
Intercom
7) IMPROVED: SIP CALL HANDLING
Published: 25/03/2025 09:17:35
Intercom